These neurochemical and glial alterations are accompanied by impa

These neurochemical and glial alterations are accompanied by impairment in locomotor activity. (C) 2012 Elsevier Inc. All rights reserved.”
“The aim of our study was to develop specific enzyme-linked immunosorbent assays (ELISAs) and apply these to assess mold antigen exposure in composting plants. Sandwich ELISAs based on polyclonal antibodies to Aspergillus fumigatus (Af), Penicillium chrysogenum (Pc),

and Cladosporium herbarum (Ch) antigens were developed and validated. Reactivity to 18 different mold species was tested. To optimize extraction procedure, inhalable dust samples taken by a parallel sampler were extracted with or without homogenization. In 31 composting plants stationary pumps were installed at 4 sites to collect 124 inhalable dust samples. The newly developed ELISAs were used in addition to an anti beta-1,3-glucan ELISA to quantify learn more mold antigens. The Cladosporium ELISA showed less than 0.04% reactivity to extracts from other fungal genera, while the Af ELISA demonstrated a reactivity of up to 3.6% and the Pc ELISA reacted up to 11% to ZD1839 other mold species. Extraction of parallel sampled filters gave higher antigen amounts with homogenization. The increase was highest

for Pc-antigens, followed by Af-antigens, and lowest for Ch-antigens. Mean lower detection limits of homogenized inhalable dust samples were 5 ng/m(3) (Af), 0.6 ng/m(3) (Pc), 0.2 ng/m(3) (Ch), and 0.6 ng/m(3) (beta-1,3-glucan). The ELISAs were able to detect antigens in 43% (Af), 37% (Pc), 94% (Ch), or 100% (beta-1,3-glucan) of the 124 airborne dust samples. Inhalable dust, FAD beta-1,3-glucan, and Af-, Pc-, and Ch-antigen concentrations were significantly correlated. The newly developed mold antigen ELISAs are thus able to measure airborne exposure

levels in composting plants and differentiate between distinct fungi genera.”
“Introduction: Orthostatic hypotension (OH) is associated with troublesome symptoms and increased mortality. It is treatable and deserving of accurate diagnosis. This can be time consuming. The current reference standard for its diagnosis is head-up tilt (HUT) testing with continuous beat-to-beat plethysmography. Our objective was to assess the accuracy of sit-stand testing with semi-automatic sphygmomanometry for the diagnosis of OH.

Design: Retrospective test of diagnostic accuracy.

Methods: This was a retrospective study performed using a database maintained by a busy syncope unit. HUT testing was performed using an automated tilt table with Finometer monitoring. A 3 min 70 degrees HUT was performed following 5 min supine. Sitting blood pressure (BP) was measured following 3 min rest. Standing BP was measured within 30 s of assuming the upright posture. The results of sit-stand testing were compared with HUT testing as a reference standard.